bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 40 of 52
Example:
Isolator
(DBA-8Z)
Address
Range
SW6
Position
SW7 setting
Comment
1
103-107
1
(1-8)
2, 4 ON
(+102)
Choose 1-8 then add offset +102
2
108-112
2
(5-12)
1, 2, 4 ON
(+103) Choose 5-12 then add 103
3
114-122
4
(13-20)
1, 4 ON
(+101)
Choose 13-20 then add 101
In the example above, Isolators 1 and 2 use only five phone connections each; the last
three outputs of Isolator 1 would be 108, 109, 110 which, although unused, conflict with
the first 3 addresses of Isolator 2; similarly with Isolators 2 and 3. Solution: disable the last
three outputs of each isolator.
Disabling phone outputs:
(Note 1st and 2nd phones cannot be disabled)
SW7 setting
Phone
1
Phone
2
Phone
3
Phone
4
Phone
5
Phone
6
Phone
7
Phone
8
[1234567i]
Seven Phones Used
disabled
[123456ui]
Six Phones Used
disabled
disabled
[12345yui]
Five Phones Used
disabled
disabled
disabled
[1234tyui]
Four Phones Used
disabled
disabled
disabled
disabled
[123rtyui]
Three Phones Used
disabled
disabled
disabled
disabled
disabled
[12ertyui]
Two Phones Used
disabled
disabled
disabled
disabled
disabled
disabled
1. On the DBA-8Z isolator set SW7 from the table above:
2. Set SW6 to 0
3. Press the Test button briefly and confirm the Status LED flashes (2 sec. duration)
4. If required confirm the output status by following the directions below.
5. Return SW6 & SW7 to the correct address setting for the Isolator
Confirming status of Isolator Outputs
To confirm which phone outputs have been disabled, set SW6 to 0 and SW7 to ‘All OFF’
and press the Test button; each output will have its status LED flash once in turn except
those outputs which have been disabled. Note it may be necessary to press the Test
button a second time on a live system to ensure that the PCB has been reset.