bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 18 of 52
Cable Distances
Connection
No.
of
cores
Cable
length
Core
Type
Phone connections
DBA-4I/8Z to 1 x 801, 801S or 801PS phone
5
70m
CAT5
DBA-4I/8Z to 2 x 801, 801S or 801PS phones (in
the same dwelling)
5
35m
DBA-4I/8Z to 1 x BS-LX phone
7
65m
DBA-4I/8Z to 2 x BS-LX phones
( in the same dwelling)
7
30m
Entrance to Control equipment (BFD-DIG Door controller)
Entrance Panel BGP-Audio
Also /PR, -LCP, LCP/PR
2x
8
50m
1.0 mm
2
CAT5
PAX1 Fob reader (extra to any entrance panel)
+3
Lock release
0.5A
4
CAT5
1A
8
1A
2
1.0mm
2
Exit button
2
CAT5
Door monitor contact / switch
2
System Interconnections
DBA-4I / DBA-8Z to Power Supply/BFD-DIG
8
**2
CAT5
BFD-DIG to BFD-DIG
+ Trades facility (optional)
6
+1
**1
Misc
Power Supply to BFD-DIG
2
3m
1.0mm
2
TS2000-BST Time clock to BFD-DIG Door
controller (optional)
4
50m
CAT5
**1
There is no restriction on this distance, except, the maximum overall cable distance
between the furthest 2 points (entrance panel to phone via the control equipment)
on the system must not exceed 300m.
**2
Refer to the cable overview diagrams 1, 2, 3, 4 or 5
For larger cable distances please contact the manufacturer.