BFD-DIG Door Controller Settings
The BFD-DIG is programmed from the panel for all settings.
Security
It is strongly recommended that the Panel Security Code be changed from its factory
setting to prevent unauthorised access. Record the new number carefully as it cannot be
easily changed if lost. It is also recommended that the Phone Programming Code, Coded
Access Code and Trades Access Code are all changed from default even if not used.
To access panel programming without the code requires physical access to the controller
PCB, borrow a jumper from say video gain (remember the setting) and place it on the 6 pin
programming header between pins 5 & 6. Now pressing the test button will enter panel
programming for 30S when the panel security code can be read or set. When the
programming is finished replace the jumper back to its original location.
Panel Programming
First type the Panel Security Code (initially [3434]) followed by the
bell
button.
The display will show the first programmable parameter and the current value.
Numeric Entry
Bell Button Toggles Value
Press the
key
button to step down through the programmable parameters.
Press the
reception
button to step up through the programmable parameters.
N.B. The display may take up to 2 Seconds to refresh.
The list rolls over bottom to top and vice versa.
To change a numeric parameter simply type a new 1-4 digit value and then press
bell
.
To change other values simply press
bell
to choose the next value.
To exit Panel Program Mode press
cancel
.
If no button is pressed for 30 seconds then programming mode will auto-cancel.