![BELL LABS INNOVATIONS Lucent Technologies MERLIN MAGIX Скачать руководство пользователя страница 263](http://html.mh-extra.com/html/bell-labs-innovations/lucent-technologies-merlin-magix/lucent-technologies-merlin-magix_installation-spm-maintenance-and-troubleshooting-supplement_2728468263.webp)
Board Renumbering with the 016 MLX Module
8-85
System Programming Maintenance
13. Print a Group Calling Information report, and compare it to the Group
Calling Information report you printed in Step 5. Since Calling Group
extensions may reverse themselves after a Board Renumber, verify that the
extension numbers are in the correct order. If the extensions are reversed,
re-program as necessary to put in correct order.
14. Print a new Group Coverage Information report and compare it to the
previous Group Coverage Information report. Verify that the appropriate
members are in the group. Program as necessary to match the previously
printed report.
15. Program the buttons that were identified in Step 8 that previously pointed to
the extensions on the 016 T/R module you replaced.
16. If additional 016 MLX modules are to be added, repeat ALL of the above
steps. If not, go to Step 17.
17. If phantom modules were programmed, re-program the phantom modules,
as needed using the information in the Extension Information reports
printed in Step 3.
18. Program the new extension ports to meet the customer’s needs.
19. Back up the system to a new filename to keep the first backup intact. Use a
filename that describes the post-016 MLX configuration-for example, “post-
016 MLX.”
Because the extension type changed for the T/R extensions, these
buttons may not be needed. Confirm the need with the customer
before restoring.
Содержание Lucent Technologies MERLIN MAGIX
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...