Upgrading from a MERLIN LEGEND System
7-3
Upgrading to MERLIN MAGIX Release 1.5
Upgrading from a MERLIN
LEGEND System
7
Many customers want to use the capabilities of a MERLIN MAGIX system
(especially the 100R INA module) without overhauling their entire MERLIN
LEGEND system. To accomplish this, you can encase the modules introduced
in the MERLIN MAGIX system in a plastic shell and place them into the
MERLIN LEGEND plastic carrier (see instructions “Installing and Removing the
Plastic Shell” on page 7-5). You also can add a metal expansion carrier to any
MERLIN LEGEND system that has one or two plastic carriers and place
modules into the metal carrier. (Three carriers is the maximum for the system.)
You can place the following modules into a plastic or metal carrier:
■
100 DCD
■
100 DS1
■
400 E&M
■
408 GS/LS-ID-MLX
■
412 LS-ID-TDL module
■
800 DID
■
800 LS-ID
■
800 NI-BRI
■
008 MLX
■
008 OPT
■
016 ETR
■
016 MLX
■
016 T/R
■
The 100R INA module is supported only in the metal carrier.
■
There can be no more than one empty slot in the preceding
plastic carrier.
Содержание Lucent Technologies MERLIN MAGIX
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...