![BELL LABS INNOVATIONS Lucent Technologies MERLIN MAGIX Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/bell-labs-innovations/lucent-technologies-merlin-magix/lucent-technologies-merlin-magix_installation-spm-maintenance-and-troubleshooting-supplement_2728468111.webp)
New Programming Options
4-15
100R INA and 100 DCD Modules
New Programming Options
4
The 100R INA and 100 DCD modules use many of the same programming
options as the 100 DS1 module. However, the 100R INA module has two new
programming options: Activate/Deactivate the On-Board CSU and Channel
Selection. The 100 DCD module has the same programming options, plus two
additional ones: Activate/Deactivate the DSU and Programming Data Port
Parameters. Along with these new options, this section also covers some
preexisting options which have changed because of the 100R INA and 100
DCD modules.
Activate/Deactivate the CSU
4
The built-in CSU is factory-set as activated on the 100R INA module and
factory-set as deactivated on the 100 DCD module. It can be reached by using
the following sequence:
Console Procedure
SysProg
→
Start
→
Lines and Trunks
→
More
→
More
→
CSU/DSU
→
Type Slot no.
→
Enter
→
ActivateCSU
→
Select
Activated
or
Deactivated
→
Enter
PC Procedure
→
→
→
More
→
More
→
→
Type Slot
no.
→
1
→
→
Select
Activated
or
Deactivated
→
Line and trunk administration for the 100R INA and 100 DCD modules
is the same as the 100 DS1 module. Each 100R INA module’s line
and trunk settings must be configured for T1 or PRI before it can be
used by the system and/or router. The 100R INA and 100 DCD
modules are set to T1 by default.
Changing the CSU setting may affect voice calls. The system
waits until it is idle before activating or deactivating the CSU.
Содержание Lucent Technologies MERLIN MAGIX
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...