Board Renumbering with the 016 MLX Module
8-83
System Programming Maintenance
19. Program the buttons that were identified in Step 8 that previously pointed to
the extensions on the 008 OPT module you replaced.
20. If additional 016 MLX modules are to be added, repeat ALL of the above
steps. If not, go to Step 21.
21. If phantom modules were programmed, re-program the phantom modules,
as needed using the information in the Extension Information reports
printed in Step 3.
22. Program the new extension ports to meet the customer’s needs.
23. Back up the system to a new filename to keep the first backup intact. Use a
filename that describes the post-016 MLX configuration-for example, “post-
016 MLX.”
Replacing a 016 T/R Module with a
016 MLX Module
8
WARNING:
If you are replacing more than one 016 T/R module, repeat Steps 1-15 for
each module. Do not try to replace more than one 016 T/R module at a
time, because the system translations will be and you will need to
completely reprogram the entire system manually to restore the
customer’s configuration.
Because the extension type changed for the T/R extensions, these
buttons may not be needed. Confirm the need with the customer
before restoring.
This procedure removes any T/R or single-line telephone functionality,
any features that may have been programmed, any buttons (for
example Inside Auto Dial) that point to those extensions.
Содержание Lucent Technologies MERLIN MAGIX
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...