Reassigning Business Cordless 905 Line Buttons
5-18
Installation, SPM, Maintenance, and Troubleshooting Supplement
c.
Enter the extension number you want to program.
d.
Select each line button to remove the factory-set line assignments and
turn off the green (G) LED.
2.
Remove the factory-set ICOM Voice button and assign it to
Button 2 on the BC 905 telephone:
a.
From the System Programming menu, select
Cntr-Prg
(
).
b.
b.From the Centralized Programming menu, select
Program
extension
(
).
c.
Enter the extension number and select
Enter
(
).
d.
Select
Start
(
).
e.
Select Button 2 on the console or PC (maps to Button 3 on the BC 905
telephone).
f.
Select
Delete
(
).
g.
Select Button 6 on the console or PC (maps to Button 2 on the BC 905
telephone).
h.
Enter
*16
to assign an ICOM Ring button. Then select Button 6 on the
console or PC again, and enter
*19
to change the attribute to ICOM
Voice.
i.
Save your entry by selecting
Enter
(
).
j.
Exit to the System Programming menu.
3.
Assign the lines to buttons in the order shown in Figure 5-10:
a.
From the System Programming menu, select
Extensions
(
).
b.
From the Extensions menu, select
Lines/Trunks
(
).
c.
Enter the extension number you want to program.
d.
Assign Line 1 to Button 3 on the BC 905 by selecting
Line 1 on the console or PC (
8
+
). Line 1 is assigned to
Button 3 on the BC 905 telephone.
e.
Assign placeholder lines to virtual buttons:
Содержание Lucent Technologies MERLIN MAGIX
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...