System Requirements & Installation
Upgrading
• The LTC source must be locked to the same reference signal. Count down time
code is not yet supported as an LTC source, in this context.
• The Reference Source must be set to
External
(either from the card’s REFERENCE
menu or, in iControl, from the
Input
tab on the control panel for this card).
• The URS Generation Mode must be set to
Normal
(either from the card’s
REFERENCE menu or, in iControl, from the
Mode
tab on the control panel for this
card).
Upgrading
Upgrade packages are made available either on a DVD or via download from a Miranda FTP
server. The upgrade package contains:
• the Kaleido-X Upgrade Manager application (
.exe
) required to upgrade the Kaleido-X,
Kaleido-X16, and KMV-3901/3911 multi-viewers
• one or more Kaleido-X operating system (
.os
or
.run
) files
• documentation, including the Release Notes
If you do not have the upgrade package, please contact
.
If you have a cascade system, refer to the “Cascade Upgrade” section, in the
Cascade Step-by-
Step Configuration
In the case of a Kaleido-IP multi-viewer, the upgrade is performed from your PC or laptop,
by using XAdmin. See
Upgrading Your Kaleido-IP Multi-Viewer to Kaleido-X Version 6.51
Notes
• If the REF-1801 is configured properly, the Status LED on the front of the
card will be green. Improper configuration would result in periodical time
code glitches.
• Refer to the
REF-1801 HD/SD Frame Reference Module Guide to Installation
and Operation
(Part No. M845-9900-100) for more information.
IMPORTANT
Cluster and cascade systems
All multi-viewers that are part of a cluster or cascade system must have the
same Kaleido-X software version.
Cluster backups you create with version 6.50 (or later), cannot be restored by
using an earlier version of XEdit. Miranda recommends you make a backup
of the individual databases for every cluster member,
before upgrading
from
a pre-6.50 version, to version 6.50 or later.
Note:
If you are upgrading a Kaleido-IP that currently has a Kaleido-X
version
earlier than 6.20,
the workflow will be slightly different. You may
want to refer to the upgrade instructions in the Release Notes for Kaleido-X
version
6.20. Make sure to review the related known issues: Ref. #31094 on
, Ref. #32001 on
, and Ref. #33687 on
.