19
Kaleido-X
Release Notes
consideration for keeping a master card in the system, or not waiting long enough for
cards to have booted completely before swapping them, can lead to serious problems.
Workaround:
(1) Remove all KXO and KXI cards. (2) Insert a card that has the most recent
software version. (3) Insert the remaining KXO cards one by one, allowing time for the
software rebuild and a complete reboot. (4) Insert the KXI cards one by one, allowing
time for the software rebuild and a complete reboot. Please refer to
on page 49, for more information.
•
[Ref. #20523]
Restarting an expansion system with an expansion card missing or a
disconnected expansion cable is not supported. If you reseat missing expansion cards
or reconnect expansion cables, an IP address conflict will be reported.
Workaround:
Restart the expansion system after reseating any missing expansion card,
and making sure both expansion cables are connected.
•
[Ref. #17359/13528]
Audio monitoring:
Audio playback is ~37 ms ahead of video, due to
an inherent processing limitation.
Workaround:
It is possible to compensate for this delay using the audio monitoring delay
calibration introduced in version 3.00.
•
[Ref. #22910]
Non-functional connection on Audio I/O TBA for the Kaleido-X16:
The PC
In analog audio ports on the Kaleido-X16’s Audio I/O terminal block adapter (TBA) are
not functional in the current release of the Kaleido-X software.
•
Non-functional connections on Kaleido-X16:
OPTION, PC In 1 Left, PC In 1 Right, PC In
2 Left, PC In 2 Right.
•
Non-functional connections on KXO-DUAL/KXO-DUAL3:
OPTION 1, OPTION 2.
•
Non-functional buttons on Kaleido-RCP2:
ALARM INHIBIT, SAVE.
•
Non-functional connections on KXI-DVI-Bridge:
ETH 10/100.
Monitor Wall
[Ref. #KX-6287]
Audio monitors:
Although valid calibration values for out of phase
sensitivity are between -1 and 1, XEdit lets you set the threshold for an audio monitor’s
phase meter to a value that is outside of the valid range, after which audio monitors
may turn gray or unresponsive on the monitor wall.
Workaround:
To recover from such a situation, set the phase meter threshold back to a
valid value (between -1 and 1) and then restart your multiviewer.
[Ref. #37307]
NV9000 alias changes:
Alias changes performed in NV9000-SE Utilities may
sometimes fail to be reflected on the monitor wall.
Workaround:
Refresh the layout on the monitor wall.
[Ref. #37154]
Polish teletext:
When WST teletext in Polish is displayed on the monitor
wall, accented characters may appear incorrectly.
[Ref. #36618]
Virtual alarms:
Changing a virtual alarm’s name in XEdit may result in its
status becoming unavailable on the monitor wall.
Workaround:
Refresh the layout on the monitor wall.
Note:
If you wished to convert your expansion system to two separate
Kaleido-X (7RU) systems, please refer to “Splitting an Expansion Frame” in
the
Kaleido-X (7RU) Hardware Description & Installation Manual
.