34
It is important that the existing installation is correct and
that the flue is performing satisfactorily. Any remedial
work necessary should be completed before the new
appliance is commissioned. Please read the Important
Information section on page 5.
WARNING: Renewal firefronts are fitted with an
Atmospheric Sensing Device (A.S.D.). If they are
installed in conjunction with a boiler NOT fitted with
an A.S.D. (i.e. 401, 552, 45/3 & 57/3), under adverse
flue conditions the boiler WILL NOT shut down.
NOTE:
A permanent live is required for correct operation
of the firefront.
Boiler Modification
Additional Installation Instructions
Bermuda RG3 Renewal G.C.N
o
37 075 06A
The kit supplied with Renewal appliances provides all the
necessary components to fit a Baxi Bermuda RG3
Renewal firefront to the following Bermuda Boilers.
The Renewal Fires may be used with the following
Boilers:
Bermuda 401
G.C.N
o
44 077 49
Bermuda 552
G.C.N
o
44 077 50
Bermuda 45/3 M
G.C.N
o
44 077 61
Bermuda 45/3 E
G.C.N
o
44 077 60
Bermuda 57/3 M
G.C.N
o
44 077 63
Bermuda 57/3 E
G.C.N
o
44 077 62
Bermuda 45/4 M
G.C.N
o
44 077 71
Bermuda 45/4 E
G.C.N
o
44 077 73
Bermuda 57/4 M
G.C.N
o
44 077 72
Bermuda 57/4 E
G.C.N
o
44 077 74
Bermuda 51/5
G.C.N
o
44 075 06
Existing Fire
REMOVING THE EXISTING FIRE
Isolate the gas and electrical supply, including any
permanent live, to the combined appliance.
Remove the controls cover panel from the front of the fire.
Remove the tap control knob. Disconnect the electrical
socket from the fire plug if fitted. Remove the screws
securing the outercase to the innercase. Lift off the
outercase.
Turn the gas service tap to the "Boiler only" position by
turning
1
/
4
turn clockwise.
Remove the radiants if fitted.
Disconnect the supply pipe at the fire inlet.
Remove any screws securing the fire to the wall. Pull the
fire forward until the flue spigot is clear of the boiler hood
and lift away.
Remove and discard the fire supply pipe from the service
gas tap. Disconnect and discard any electrical wiring
between the boiler input terminal and the fire.
Adhesive Foil Label
Renewal Firefront
NOTE: It is important at this stage to fit the
controls heat shield supplied with the fire unit to
the boiler front panel.
Remove and discard the controls heat shield
provided with the boiler and fit the new controls heat
shield using the screws previously removed.
Fit the additional valve heat shield in position over
the gas valve by engaging the two clips and pushing
home as shown above.
Check the data badge on the back boiler. If the boiler
internal wiring is not depicted, take the foil label from
the kit and attach it below the data badge on the
boiler front door.
If a radiant firefront has been installed previously it
will be necessary to unscrew and remove the
extension plate from the boiler controls heat shield.
Once removed this item can be discarded.
BERMUDA 401 & 552
New Controls
Heat Shield
Controls Heat
Shield
Valve Heat
Shield
BERMUDA 45/3, 57/3, 45/4, 57/4 & 51/5
Extension Plate
Bermuda 57/3 Illustrated