Manual Control Models
If the fire supply cable has not been fitted when wiring
the boiler proceed as follows:-
CONNECTING ELECTRICAL SUPPLY TO
THE BOILER
Connect the wiring to the boiler as
follows:-
Extract the screw that fixes the boiler
controls connection plug to the socket
on the boiler base tray and disconnect
the plug. Retain the screw.
Extract the screw that fixes the socket to the boiler
base tray and remove the socket by sliding it to the
right. Retain the screw.
Extract the screw that fixes the cover to the
socket housing and remove the cover to
reveal the terminals and cable clamps.
Retain the screw.
The switched live must be connected
to the terminal marked "L1".
The permanent live must be connected
to one of the terminals marked "L2".
The neutral must be connected to one of the
terminals marked "N".
Route the green and yellow wire (EARTH) through the
cut-out in the socket housing and connect it to the
earth terminal on the boiler base tray.
NOTE:- The earth wire should be sufficiently long,
so that if the supply cable is pulled on, the live
and neutral wires will become taut before the earth
wire.
Secure the cable in the socket with the cable clamp.
For 3-core cable use the flat side of the cable clamp
downwards and for 4-core cable use with the radius
side of the cable clamp downwards.