Three clips across the top of the glass frame secure it
in position. When the clips are released, the glass
frame assembly will lean outwards to rest on its
bottom location positions, from which it can be lifted
clear of the fire. The two outer clips should be
released before the centre one. Release the clips by
gripping centrally and pulling upwards.
Remove the packing piece that retains the
coalbed and lift the coalbed clear of its
location pegs.
CAUTION:- The coalbed is extremely
fragile and must be handled
accordingly. Gloves should be worn
and any inhalation of the dust should
be avoided. Keep the coals away
from children at all times.
Please read the Important
Information section on page 4.
Check that the spark gap between
the electrode and thermocouple is
between 2.5 and 4mm.
Take the coalbed out of its plastic bag
and replace it in position on the burner.
Replace the glass frame assembly by lowering it into
its bottom locating positions and, whilst holding
against the rope seal, engage the retaining clips. To
engage the clips, locate the front of the clip over the
top edge of the glass frame and push the top of
the clip downwards. The centre clip should be
replaced before the outer clips.
Turn on the mains gas and electricity
supplies.
Turn the gas service cock to the fire and boiler ON
position by turning fully anti-clockwise, then purge
according to in GB BS 6891 and in IE the current
edition of I.S. 813 “Domestic Gas Installations”.
Check for gas soundness from the gas service cock to
the fire inlet position.
Connect the electricity supply to the fire by
fixing the 3-pin socket that comes from the
boiler into the plug provided on the fire unit.
The plug is situated towards the left, in the
space behind the lamp box.
COMMISSIONING THE FIRE
Rotate Lamp Box
Forward Using
The Handles
Handle
Socket
2.5 to 4mm
Glass Frame
Boiler/Fire
View of Boiler Controls
(Manual Model shown)
when Lamp Box is
rotated forward
16