Remove the Fire chassis as follows :-
The lamp box, which is clipped at the top and hinged
at the bottom is rotated forward to expose the boiler
controls. Use the handles provided.
Electricity is supplied to the fire by means of a 3
pin socket from the boiler. The plug is situated
towards the left in the space behind the lamp box.
Disconnect the socket from the plug on the fire and
lay it on the boiler tray.
Turn off the gas service cock on the boiler by turning
fully clockwise.
Disconnect the fire supply pipe from the fire inlet.
Clip the lamp box back into position.
If required, the top panel on the fire can be removed,
to gain better access to the lifting points. To do this,
remove the two fixing screws securing it and lift the
panel up at the front.
Remove and retain the two screws fixing the
fire chassis to the backing plate.
Pull the fire forwards until the fire flue
spigot is clear of the boiler canopy and
lift away.
Remove the Glass Frame and
Coalbed as follows :-
The 3 clips that secure the glass frame
assembly are now visible across the top
edge of the glass frame. The two outer
clips should be released before the centre
one. Release the clips by gripping centrally
and pulling upwards.
When the clips are released, the glass frame
assembly will lean outwards to rest on its bottom
location positions, from which it can be
lifted clear of the fire.
The coalbed is positioned on two
locating pins. Lift the coalbed
vertically to clear the pins.
Rotate Lamp Box
Forward Using
The Handles
Fire Supply
Pipe
Handle
Socket
Glass Frame
View of Boiler Controls
(Manual Model shown)
when Lamp Box is
rotated forward
21