Initial Preparation
Unpack the fire unit.
Electrical Connections
THIS APPLIANCE MUST BE EARTHED
NOTE: The method of connection to the electricity
supply must facilitate complete electrical isolation
of the combined appliance (Fire and Boiler).
Connection may be made via a fused double pole
isolator switch with a contact separation of at least
3mm (
1
/
8
in) in all poles. The switch should be
fused at a maximum of 3 amp and must serve the
boiler or system controls only. Alternatively, the
connection should be made via a standard 3-pin
plug, fused at a maximum of 3 amp.
Any 4-core cable used for connection to the boiler
unit must NOT be less than 0.75mm
2
(24 x 0.2mm)
PVC IEC 53 code 227 (heat resistant).
Electricity is supplied to the fire via the boiler unit.
The electrical connection between the fire and
boiler unit is made by wiring the socket and cable
assembly, that is supplied with the fire unit, into the
socket on the boiler. Ideally, this connection should
be made at the same time as the electrical
connections to the boiler unit.
b
b
N
E
L
br
r
w
Micro-Switch
Resistor
KEY
br - Brown
b - Blue
w - White
r - Red
g/y - Green & Yellow
Bulbs
Light
Switch
Spark Generator
Spark Generator
Functional Flow Diagram
Electrode
INSTALLATION
w
b
w
b
b
b
br
r
b
br
g/y
g/y
Electrode
Plug
Micro-Switch
Light Switch
Terminal Strip
Resistor
Bulb
Bulb
LAMP BOX
Pilot / A.S.D.
Assembly
8