PILOT ASSEMBLY
Remove the glass frame assembly and
coalbed.
Grip the pilot assembly and loosen
the compression nut that connects the
pilot gas supply pipe to it.
Remove the two screws that retain the
pilot assembly.
Remove the pilot gas
supply pipe and
other associated
wires out of the
location clip.
Release the pilot gas
supply pipe from the
pilot by unfastening the
compression nut.
Disconnect the electrode lead from
the electrode.
Remove the thermocouple lead from the
end of the gas control tap by unscrewing the
small retaining nut and draw the pilot assembly
out of the fire chassis.
Replace the pilot assembly in the reverse order of
removal.
NOTE:- Care should be taken not to over tighten
the nut that secures the thermocouple lead into
the end of the gas tap.
Replace the coalbed and glass frame assembly.
ELECTRO-MAGNETIC UNIT
IMPORTANT:- If the appliance is fitted with a pilot
shield, electro-magnetic unit part no.239413
should be ordered.
Appliances without a shield require part
no.082462.
Remove the thermocouple lead from the end of the
gas control tap by unscrewing the small retaining nut.
Remove the large nut that retains the electro-
magnetic unit and remove the unit from the gas
control tap.
Fit the new electro-magnetic unit and replace the
retaining nut. Fix the thermocouple back into position,
taking care not to overtighten the retaining nut.
Glass Frame
Thermocouple
Lead
Gas Control Tap
Pilot Assembly
Pilot Gas
Supply Pipe
Electrode Lead
Electro-Magnetic Unit
27