Electronic Controls Models
If the boiler electrical connections have
already been made, ensure that the
electrical supply to the boiler is
isolated. The fire should always
be electrically connected as
described below and must not
be provided with an electrical
connection that is independent
from the boiler.
Remove the controls heat shield
from its retaining clips.
Remove the electrical inlet socket
from the PCB at the rear left hand
side of the control box.
Remove the socket cover. The socket should be wired
as described in the boiler Installation and Servicing
Instructions.
If the firefront being installed is
equipped with either lighting
effects or lighting effects and
electronic ignition the plug
must be wired as shown:
Connect the control
switched live to L.
Connect neutral to N.
Connect earth to .
The live of the fire supply
cable must also be connected
to the terminal block.
Neutral and Earth of the fire supply cable can then be
connected to N and respectively.
If the firefront does not require a permanent live feed,
wire the plug as shown. The loose terminal block can
be discarded.
Refit the cable clamp ensuring that the outer
insulation is securely held and refit the socket cover.
Ensure that all cables are routed away from the
boiler casing and hood.
Controls Heat
Shield
11
SL
L
N
SL
L
N
SL
L
N
Loop
Loose
Terminal
Block
Cut the end of the
earth tag from the
fire supply cable
earth wire.
From
Firefront
From Control
System &
Permanent Live