D AWHP 4.5 MR
E AWHP 6 MR-3
F AWHP 8 MR-2
1. Remove the service panel.
2. AWHP 4.5 MR only: remove the earth connection screw from the
appliance and discard.
3. Check the cross-section of the cable used, as well as its protection in
the electric panel.
4. AWHP 4.5 MR only: secure the screw and square washer provided on
the stripped part of the earth wire
.
Danger
The stripped part of the earth wire must be fitted underneath the
washer against the base frame.
5. Connect the earth wire.
Danger
The earth wire must be 10 mm longer than the N and L wires.
6. Connect the cables to the appropriate terminals.
7. Feed the cable into the cable duct and adjust the length of the cable
accordingly. Lock it in position with a cable clamp or a traction arrester
device.
Caution
Danger of electric shock: the length of the conductors between the
traction arrester device and the terminal blocks must be such that
the active conductors are put under tension before the earth
conductor.
6.8.8
Connecting the indoor module
1. Remove the front panel of the casing.
2. Fit the cable clamps and run the cables through the cable clamps.
3. Connect the power supply cable to the electric panel.
4. Connect the various components to the corresponding terminals on
the indoor module.
5. Connect the electrical back-up.
6. Tighten the cable clamps.
7. Put the front panel back in place.
Fig.46
MW-1001217-1
1
2
D
E
F
230V~
NEW
4
5
6
7
230V~
L
N
10mm
7
7
1
1
6 Installation
44
7762758 - v05 - 19082020