Tab.70 Parameters menu
Parameter
Description
Factory setting
MaxZoneTFlowSetpoi
nt (CP000)
Maximum Flow Temperature setpoint zone
CIRCA0: can be set from 7 °C to 75 °C
Electrical back-up: 75
Zone Function
(CP020)
Type of CIRCA0 connected to the EHC–05 PCB:
Disable = heating circuit deactivated
Direct = radiators. Cooling not possible.
Mixing Circuit = underfloor heating. Cooling possible.
Swimming pool = not available
High Temperature = not used
Fan Convector = convection fan. Cooling possible.
Direct
MaxReducedRoomT.
Lim (CP070)
Max Room Temperature limit of the circuit in reduced mode, that allows
switching to comfort mode
Can be set from 5 °C to 30 °C
16
Zone HCZP Comfort
(CP210)
Comfort footpoint of the temperature of heat curve of the circuit
can be set from 16 to 90 °C
set to 15 = the curve base temperature is set automatically and is the same
as the room set point temperature
15
Zone HCZP Reduced
(CP220)
Reduced footpoint of the temperature of heat curve of the circuit
can be set from 6 to 90 °C
set to 15 = the curve base temperature is set automatically and is the same
as the room set point temperature
15
Zone Heating Curve
(CP230)
Heating curve temperature gradient of the zone
Can be set from 0 to 4
1.5
ZoneRoomUnitInfl
(CP240)
Adjustment of the influence of the zone room unit
Can be set from 0 to 10
3
TypeReducedNightM
ode (CP340)
Parameter linked to
the CP070 parameter
Type of reduced night mode, stop or maintain heating of circuit
Stop heat demand: heating is deactivated when the room set point tempera
ture set in the timer programme is below the threshold set in CP070.
Continue heat demand: the heating set point is maintained independently of
the threshold set in CP070.
Stop heat demand
Control strategy
(CP780)
Selection of the control strategy for the zone
Automatic
Room Temp. based
Outdoor Temp. based
Outdoor & room based
Automatic
9.4.2
Installation Setup > Stratified DHW tank > Parameters,
counters, signals
A domestic hot water sensor must be connected to the EHC–05 PCB to
display these parameters. The Stratified DHW tank circuit is on the EHC–
05 PCB.
Tab.71 Parameters menu
Parameter
Description
Factory setting
DhwMaxTemp
(DP046)
Max. flow temperature for domestic hot water production.
Can be set from 10 to 70 °C
70 °C
Max. DHW duration
(DP047)
Maximum authorised duration for domestic hot water production.
Can be set from 1 to 10 hours
3 hours
Min. CH before DHW
(DP048)
Minimum heating duration between two domestic hot water production runs.
Can be set from 0 to 10 hours
2 hours
9 Settings
68