Technical Data
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
35
3
3.4
Electrical data
3.4.1
Electrical data BM3002
1)
All rated values refer to a supply voltage of 400 V at 50 Hz and an environmental temperature of 40 °C.
BM3002
Input rated power output
1)
18 kVA
Input rated current (I
eff
)
1)
28 A
Distortion factor of the input current (THD
I
)
110 %
10 %
DC-link voltage depends on power supply,
rated value
1)
540 V
DC
at U
power supply
= 3 x 400 V
Max. sum of DC-link capacitance within the DC-link
18 mF
Waiting time between 2 charging processes with exter-
nal connected DC-link capacitance
Connectable load to the DC-link
15 kW
Switch on ready-to-operate after
depends on the external
capacitance
Power loss referring to power connection
50 W
Power loss referring to control voltage
max. 2 W
C
ext
U
power supply
2
400
------------------------------------------------