Fieldbus communication
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
160
8.6
8.6.2
VARAN
.
Type code
BM3200, BM3300
with VARAN:
BM3XXX-XXXX-XXXXX[-X]-
2
XXXX[-S0X]-XX[-XX][-EXX][-#XX]
A
BM3200, BM3300
with fieldbus option VARAN can communicate with a VARAN mas-
ter.
X3
and
X4
on the front side of the device are the RJ45 connections for VARAN (also see
Mounting and in-
stallation
The mounting/installation consists of the following steps:
1
De-energize the
BM3200, BM3300
device
2
Set the
BM3200, BM3300
IP-address,
3
Connect
BM3200, BM3300
with VARAN bus cables
(Ethernet-LAN cable at least CAT 5).
n
X3: VARAN-In, X4: VARAN-Out.
On the first
BM3200, BM3300
node of a VARAN line X3 is connected with the VA-
RAN master. X4 is connected with X3 of the next
BM3200, BM3300
slave in the line,
and so on. The last node of a VARAN line has no connection of X4 or is connected
with a PC (tunneling of Ethernet frames via VARAN to the controller, e. g. to com-
municate with ProDrive).
Each slave within the VARAN line can be addressed and parametrized via selection
of its IP address.
Abbildung 68: VARAN fieldbus connection
NOTE!
A point-to-point connection between PC (ProDrive) and
BM3200, BM3300
VARAN
slave X4 for commissioning is possible even without a VARAN master.
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......