Installation
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
131
7
Sine or
square wave
encoder
evaluation
The encoders, which meet the following technical specifications, can be used:
Voltage supply
5 V
DC
controlled
Signal level
RS422 (TTL) for square wave incremental encoders
~1 Vss for sine incremental encoders
Current input
Max. 250 mA
D-sub-connector
26-pin
1
GND encoder supply
2
+5 V encoder supply
3
reserved *
4
RS422 A +
5
RS422 A -
6
RS422 B +
7
RS422 B -
8
RS422 0 +
9
RS422 0 -
10
reserved *
11
Sense GND
12
Sense V
CC
13
reserved *
14
reserved *
15
reserved *
16
reserved *
17
Tempe
18
Temperature -
19
reserved *
20
reserved *
21
reserved *
22
reserved *
21
reserved *
22
reserved *
23
reserved *
24
reserved *
25
reserved *
26
reserved *
* do not occupy
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......