Installation
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
121
7
7.14.1.2 X2 - Digital inputs/outputs
X2
(SELV/PELV)
Inputs:
Evaluation:
Edges, programmable
Current input according to input:
2 mA digital input,
20 mA fast digital input
Transit delay input:
Max. 4 ms, 10 µs at fast inputs
Level:
Low (0 ... 5 V); High (12 ... 28 V)
Outputs:
Output current per output:
500 mA
Electrical isolation:
Optocoupler
Short-circuit proof:
Current-limited
Differing from this are pin No. 6,7: NO contact, ungrounded
Loading capability per NO contact:
max. 30 V, max. 100 mA
Max. conductor cross-section
Termination system
1.0 mm²
Connector,
spring clamp termination
NOTE!
A relay with varistor protection circuit is required in case the customer connects a re-
lay to a digital output.
1
M24V (supply digital input/output)
2
Digital input 1 (touch probe 1)
3
Digital input 2 (touch probe 2)
4
Digital
input
3
5
Digital input 4 (pulse enable)
6
Ready-to-operate
7
Ready-to-operate
8
Digital output 1
9
Digital output 2
10
+24V (supply digital input/output)
1
5
6
10
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......