Technical Data
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
39
3
Footnotes see
BM3X02
1-phase/1 x 400 V
BM3X03
1-phase/1 x 400 V
BM3X04
1-phase/1 x 400 V
Input rated power output
1)
1.2 kVA
1.4 kVA
Input rated current (I
eff
)
1) 2) 3)
4.2 A
5.6 A
Distortion factor of the input current (THD
I
)
1)
130 %
Input peak current (I
eff
)
1) 2) 3)
5.6 A
DC-link voltage power supply-dependent/rating
540 V
DC
DC-link capacitance (internal), external not permitted
235 µF
DC-link discharge time (internal DC-link capacitance)
ca. 450 s
Output voltage
(U
AC
)
1) 4)
0 ... 400 V
Output frequency at 4 kHz
5) 6)
0 ... 450 Hz
Output rated current
(I
AC
)
1)4)7)8)9)
at 2 kHz
5)
2 A
Output rated current (I
AC
)
1)4)7)8)9)
at 4 kHz
5)
2 A
Output rated current
(I
AC
)
1)4)7)8)9)
at 8 kHz
5)
2 A
Output rated current (I
AC
)
1)4)7)8)9)
at 16 kHz
5)
2 A
Output peak current (I
AC
)
1)4)7)8)9)
at 2 kHz
5)
2 A
Output peak current
(I
AC
)
1)4)7)8)9)
at 4 kHz
5)
2 A
Output peak current (I
AC
)
1)4)7)8)9)
at 8 kHz
5)
2 A
Output peak current
(I
AC
)
1)4)7)8)9)
at 16 kHz
5)
2 A
Ballast start-up voltage
785 V
Ballast peak power, internal ballast resistor
a)
1200 W for max. 150 ms
Average ballast power, internal ballast resistor
a)
100 W
Permitted ballast current (Î), external ballast resistor
b)
max. 7.0 A
Ballast resistor, external ballast resistor
b)
111
Ballast peak power, external ballast resistor
b)
5.5 kW
Permitted continuous power of external ballast resistor
b)
2.5 kW
Switch on ready-to-operate after
4 s
Max. upload time
0,5 s
Power loss referring to power connection
50 W
Power loss referring to control voltage
max. 30 W
Cooling air requirement
11 m
3
/h
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......