Shielding plan
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
94
7.8
5
connect both shielding with shield clamp on the shield sheet,
note locking torque of the fixing screw!
Shield sheet
Fixing
screw
Shielding
clamp
Motor cable
Figure 36:
Shield connection motor cable
Motor tempera-
ture cable
Wrapping with
metallic adhe-
sive tape
Locking torque of the fixing screw:
NOTE!
The shield must be connected to the mounting plate with a metallic clamp, if the op-
tional shield sheet is not used!
Shielding clamp width
Locking torque
shielding clamp width 24 mm width
0.8 Nm
cable diameter 5 - 20 mm
shielding clamp width 17 mm width
0.8 Nm
cable diameter 3 - 14 mm