Connections
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
122
7.14
7.14.1.3 X3 / X4 - fieldbus connection
Depending on the hardware-version, see
EtherCAT
®
Type code
BM3200, BM3300
with EtherCAT
®
CoE profile:
BM3XXX-XXXX-XXXXX[-X]-
1
XXXX[-S0X]-XX[-XX][-EXX][-#XX]
Type code
BM3200, BM3300
with EtherCAT
®
SoE profile:
BM3XXX-XXXX-XXXXX[-X]-
7
XXXX[-S0X]-XX[-XX][-EXX][-#XX]
X3
X4
EtherCAT
®
IN
EtherCAT
®
OUT
Number of bus connections
1 IN / 1 OUT
Bus connection
RJ 45
Number of parameters
refer to
parameter handbook BM3000
Data width of parameters
16 / 32 Bit
Baud rates
10 / 100 Mbit/s
1
: TX+
2
: TX-
3
: RX+
4
: reserved
5
: reserved
6
: RX-
7
: reserved
8
: reserved
X3
X4