Connecting diagrams
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
116
7.12
7.12.7 Application: DC link connection of further BM3000 or of additional capacities
+ 24 V
M 24 V
X2:1
X2:5
X2:10
X200-1
F4
3300_0077_rev01_int.cdr
1C1
1D1
1U1
1V1
1W1
X200
X205
X202
X300
X2:1
X2:5
X2:10
X200-1
1C1
1D1
1U1
1V1
1W1
X200
X205
X202
X300
X2:1
X2:5
X2:10
X200-1
-2
1C1
1D1
1U1
1V1
1W1
X200
X205
X202
X300
-2
PE
3
M3
-2
L1
L2
L3
1U2
1V2
1W2
PE
3
M2
1U2
1V2
1W2
PE
3
M1
1U2
1V2
1W2
PE
F11
F10
F1
ENC
ENC
ENC
Filter
L (off)
H (on)
L (off)
H (on)
L (off)
H (on)
F13
F12
F15
F14
for devices with 3-phase connection and internal ballast resistor
BM3XXX
-X
T
XX-XXXXX-
B
-XXXXX-
Figure 49:
Example: Further devices connected to the DC link
NOTE!
Following notes must be considered if additional devices or capacities are connected
to the DC link.
The sum of the drawn power of all devices (incl. the supply unit) must be lower than
5 kW
.
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......