Monitoring functions
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
174
10.2
Block monitoring
This monitoring function checks the motor speed and the motor current.
If both of the following conditions are met for the period „block monitoring time“, then the
error/the warning „drive blocked“ is signaled to the controller and an immediate pulse in-
hibit takes place.
m
Motor speed = 0
m
The motor current output from the device is the same as the set motor limit current (cur-
rent limit).
Signal bus
All power units at the axis devices are connected with a „signal bus“. Each user can re-
quest for and set the bus signals including the supply unit.
Signal bus - supply ready-for-use
Indicates, when the supply unit is in the status „ready-for-use“. This signal is generated
after the recognition and identification of the power supply. At a power rectifier „ready-for-
use“ is active after about 4 s after switching on the 24 V-supply voltage.
At power supply errors and power supply failure the ready-for-use signal is reset. The
axes must react upon this and must change into the error state.
Signal bus - ballast resistor on
The DC-link voltage is monitored independently by each axis. The mode parameter
(140.1) bit 0 sets, if the signal for the control of the ballast resistor shall be activated at
this warning. If the voltage of the ballast resistor drops below the ballast resistor threshold
(P130.29 protected) - 20 V (hysteresis) the axis resets the signal at the bus and deletes
the warning.
The ballast resistor threshold is calculated from max. U
DC-link
with:
Ballast resistor = max. U
DC-link
- 30 V
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......