Installation
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
107
7
X1
Service interface, see
X2
Digital in- and outputs e. g. pulse enable,
see
X2:5
Input pulse enable, Low: not enabled, High: enabled (operation possible)
X3, X4
Connections for fieldbus EtherCAT
®
, VARAN, CANopen
®
, POWERLINK
®
, according to
version, also see
X6
Analog in- and outputs,
see
X7
Encoder evaluation,
see
X101
Connection motor temperature
see
X102
Connection STO
see
X102 - safe torque off - option
X107
Motor, also see
on page 28 and
X200
Connections for the 24 V-voltage supply (SELV/PELV),
see
Requirements to the control voltage / 24 V-supply
on page 28 and
X203
Connection for DC link, see
X202, X203, X205 - power supply, DC link, ballast resistor
X205
Connection for the DC-link, see
X202, X203, X205 - power supply, DC link, ballast resis-
X300
Signal bus, connection to further units
see
F1
Fuse DC link
F2
Fuse for the 24 V-voltage supply
PE
PE connection,
see
PE connection and RCD compatibility
from page 89 and
PE connections BM3200, BM3300 rear panel
NOTE!
In order to comply with the standard, at the PE connection, per cable lug one nut M5
must be used!
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......