Programmable Safety Controller SCR P
www.bernstein.eu
- Tel: + 49 571 793 0
135
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
VO16 fault
VO15
fault
VO14
fault
VO13
fault
VO12
fault
VO11
fault
VO10
fault
VO9 fault
VO8 fault
VO7 fault
VO6 fault
VO5 fault
VO4 fault
VO3 fault
VO2 fault
VO1 fault
Table 25: Virtual Output Fault 17-32
PLC Input register 30006 or Holding Register 40006, also Inputs 10049-64 or Coils 00049-64
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
VO32 fault
VO31
fault
VO30
fault
VO29
fault
VO28
fault
VO27
fault
VO26
fault
VO25
fault
VO24
fault
VO23
fault
VO22
fault
VO21
fault
VO20
fault
VO19
fault
VO18
fault
VO17
fault
Table 26: Virtual Output Fault 33-48
PLC Input register 30007 or Holding Register 40007, also Inputs 10033-48 or Coils 00033-48
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
VO48 fault
VO47
fault
VO46
fault
VO45
fault
VO44
fault
VO43
fault
VO42
fault
VO41
fault
VO40
fault
VO39
fault
VO38
fault
VO37
fault
VO36
fault
VO35
fault
VO34
fault
VO33
fault
Table 27: Virtual Output Fault 49-64
PLC Input register 30008 or Holding Register 40008, also Inputs 10049-64 or Coils 00049-64
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
VO64 fault
VO63
fault
VO62
fault
VO61
fault
VO60
fault
VO59
fault
VO58
fault
VO57
fault
VO56
fault
VO55
fault
VO54
fault
VO53
fault
VO52
fault
VO51
fault
VO50
fault
VO49
fault
9.5.2 Extended Flags
All 256 Virtual Outputs can be accessed in a way similar to that seen in
Inputs 11001 through 11256 represent all 256 possible Virtual Outputs. These Virtual Outputs can also be read as Input
Registers 901-916 or Holding Registers 901-916.
Inputs 12001 through 12256 are all 256 Virtual Output Faults. These Virtual Output Faults can also be read as Input
Registers 917-932 or Holding Registers 917-932.
9.5.3 Outputs from Safety Controller (Inputs to PLC)
The Output registers are used to push output values from the Safety Controller to the PLC. MSG (message) commands are
used to Read (N7) from the Safety Controller.
Table 28: N7 REGS
REG #
WORD NAME
DATA TYPE
0
VO1
16-bit integer