• If the configuration or the passwords on the Safety Controller and the SCR P-FPS do not match, the USB
LED flashes red. If the SCR P-FPS is not disconnected from the Safety Controller within 3 seconds, the
power/fault and USB LEDs flash red and the Safety Controller enters a lockout state due to the mismatch.
7. Cycle the power.
The power/fault LED is green, the USB LED is green (if the SCR P-FPS is still plugged in) or red (no SCR P-FPS
or USB cable connected), and the Input and Ouput LEDs show actual input status.
The Safety Controller is ready for commissioning. See
Commissioning Checkout Procedure
11.8 Reset the Safety Controller to Factory Defaults
The Safety Controller must be powered up and connected to the PC via the USB cable.
1.
Click
.
2.
Click
Reset to Factory Default
.
A caution displays reminding you that all settings will change to factory defaults.
3.
Click
Continue
.
The
Enter Password
screen opens.
4.
Enter the User1 password and click
OK
.
The Safety Controller is updated to the factory default settings and a confirmation window displays.
5.
Click
OK
.
6.
Cycle the power.
The reset to factory default process is complete.
11.9 Factory Defaults
The following table lists some of the factory default settings for both the Safety Controller and the Software.
Setting
Factory Default
Applicable Product
AVM Function
50 ms
SCR P
Closed-to-Open Debounce Time
6 ms
SCR P
EDM
No monitoring
SCR P
Function Block: Bypass Block Default Nodes
IN, BP
SCR P
Function Block: Bypass Time Limit
1 s
SCR P
Function Block: Delay Block
—Default Nodes
IN
SCR P
Function Block: Delay Block
—Output Delay
100 ms
SCR P
Function Block: Enabling Device Block
—Default Nodes
ED, IN, RST
SCR P
Function Block: Enabling Device Block
—Time Limit
1 s
SCR P
Function Block: Latch Reset Block
—Default Nodes
IN, LR
SCR P
Function Block: Muting Block
—Default Nodes
IN, MP1
SCR P
Function Block: Muting Block
—Time Limit
30 s
SCR P
Function Block: Two-Hand Control Block
—Default Nodes
TC
SCR P
Industrical Ethernet: String (EtherNet/IP and PCCC Protocol) 32 bit
SCR P
Network Settings: Gateway Address
0.0.0.0
SCR P
Network Settings: IP Address
192.168.0.128
SCR P
Network Settings: Link Speed and Duplex Mode
Auto Negotiate
SCR P