3.
Select appropriate device settings:
Basic settings:
•
Name
—input device name; generated automatically and can be changed by the user
•
Circuit Type
—the circuit and signal convention options appropriate for the selected input device
•
Module
—the module to which the input device is connected
•
I/O Terminals
—the assignment of input terminals for the selected device on the selected module
•
Enable Startup Test
(where applicable)
—an optional precautionary safety input device test required
after each power-up
•
Reset Options
(where applicable)
—various reset options such as Manual Power Up, System Reset,
and Reset Track Input Group
Advanced settings (where applicable):
•
Simultaneity
(where applicable)
—Simultaneous or Concurrent (see
on p. 194 for definitions)
•
Debounce Times
—the signal state transition time
•
Monitored/Non-Monitored
(where applicable)
Figure 34: Basic Safety Input Settings