280
Standards and certifications • Requirements for immunity to disturbances (immunity)
Panel PC 800 User's Manual V 1.00
4.8 Damped oscillatory waves
DC power inputs
-
20 interruptions for 10 ms < UN -
15%, criteria A
Test carried out according to
EN 61000-4-18
Limits according to
EN 61131-2
AC power inputs
max. 2.5 kV, 1 MHz
±
10%, repeat
rate 400/seconds, length 2
seconds, connection lengths 2 m,
criteria B
DC power inputs
max. 2.5 kV, 1 MHz
±
10%, repeat
rate 400/seconds, length 2
seconds, connection lengths 2 m,
criteria B
Table 164: Test requirements - Damped oscillatory waves
Test carried out according to
EN 61000-4-11
Limits according to
EN 61000-6-2
Limits according to
EN 61131-2
Table 163: Test requirements - Voltage dips, fluctuations, and short-term interruptions (cont.)