Commissioning • Installation
Section 3
Com
m
is
sio
ning
127
Panel PC 800 User's Manual V 1.00
Chapter 3 • Commissioning
1. Installation
Panel PC 800 devices are best mounted in a housing cutout using the clamps found on the
housing (different designs possible).
The terminal blocks are designed for a maximum thickness of 10 mm for the material where the
device is being clamped.
In order to tighten or loosen the screws, a hex key (size 3) is required for the plastic clamps and
a Torx screwdriver (size 20) or a large flat-head screwdriver for the aluminum die casting.
The maximum torque when tightening the clamp is 0.5 Nm. A Panel PC 800 unit must be
mounted to a flat surface. Uneven areas can cause damage to the display when the screws are
tightened.
Figure 58: Terminal block
Plastic (PA6)
with clip
Aluminum dye cast
with clip
Aluminum dye cast
without clip
Close
Open
Close
Open
Close
Open
Clamping le
ve
r
Clamping le
ve
r
Clamping le
ve
r
Clips
Содержание MAPPC800-ENG
Страница 2: ...2 Panel PC 800 User s Manual V 1 00...
Страница 4: ...4 Panel PC 800 User s Manual V 1 00...
Страница 6: ...6 Panel PC 800 User s Manual V 1 00...
Страница 16: ...16 Panel PC 800 User s Manual V 1 00 Table of contents...
Страница 32: ...32 General information Model numbers Panel PC 800 User s Manual V 1 00...
Страница 166: ...166 Commissioning User tips for increasing the display lifespan Panel PC 800 User s Manual V 1 00...
Страница 350: ...350 Accessories Cables Panel PC 800 User s Manual V 1 00...
Страница 378: ...378 Appendix A Glossary Panel PC 800 User s Manual V 1 00...
Страница 388: ...Table index 388 Panel PC 800 User s Manual V 1 00...