58
Technical data • Entire device
Panel PC 800 User's Manual V 1.00
2.6.9 Status LEDs
The status LEDs are on the back of the system unit.
Status LEDs
LED
Color
Meaning
Power
Green
On
Supply voltage OK
Red
On
The system is in standby mode
(S5: soft-off mode or S4:
Hibernate mode -Suspend-to-
Disk)
Orange
1)
1) Only lit when add-on UPS module is installed.
On
Supply voltage not OK; the
system is operating on battery
power.
red /
green
Blinking
MTCX upgrade service
function: A red/green blinking
power LED indicates a faulty
or incomplete MTCX upgrade.
The MTCX runs using the
firmware version installed
when delivered. This could be
caused by a power failure
during an MTCX upgrade. An
MTCX upgrade must be
performed again.
HDD
Yellow
On
Signals IDE drive access (CF,
HDD, CD, etc.)
Link
Yellow
On
Indicates an active SDL
connection on the monitor /
panel plug.
Blinking
An active SDL connection has
been interrupted by a loss of
power in the display unit.
Run
Green
On
Application running
Off
Application is not running
Table 33: Data - status LEDs
Содержание MAPPC800-ENG
Страница 2: ...2 Panel PC 800 User s Manual V 1 00...
Страница 4: ...4 Panel PC 800 User s Manual V 1 00...
Страница 6: ...6 Panel PC 800 User s Manual V 1 00...
Страница 16: ...16 Panel PC 800 User s Manual V 1 00 Table of contents...
Страница 32: ...32 General information Model numbers Panel PC 800 User s Manual V 1 00...
Страница 166: ...166 Commissioning User tips for increasing the display lifespan Panel PC 800 User s Manual V 1 00...
Страница 350: ...350 Accessories Cables Panel PC 800 User s Manual V 1 00...
Страница 378: ...378 Appendix A Glossary Panel PC 800 User s Manual V 1 00...
Страница 388: ...Table index 388 Panel PC 800 User s Manual V 1 00...