Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
271
[PARAM. SET SWITCHING] (MLP-)
Code
Name/Description
Factory settings
MLP-
[PARAM. SET SWITCHING]
CHA1
[2 parameter sets]
[No]
(nO)
nO
[No]
(nO)
: Function not active.
FtA
[Thresh. Freq. err.]
(FtA)
: Switching via
[F.-Thresh. Mot]
(Ftd)
)
F2A
[Thresh. Freq. 2 err.]
(F2A)
: Switching via
[F.-Thresh. 2]
(F2d)
)
LI1
[LI1]
(LI1)
-
.
[...]
(...)
: See the assignment conditions
Switching 2 parameter sets
CHA2
[3 parameter sets]
[No]
(nO)
nO
[No]
(nO)
: Function not active.
FtA
[Thresh. Freq. err.]
(FtA)
: Switching via
[F.-Thresh. Mot]
(Ftd)
.
F2A
[Thresh. Freq. 2 err.]
(F2A)
: Switching via
[F.-Thresh. 2]
(F2d)
)
LI1
[LI1]
(LI1)
-
.
[...]
(...)
: See the assignment conditions
Switching 3 parameter sets
Note:
To obtain 3 parameter sets,
[2 param. sets]
must also be configured.
[PARAMETER SELECTION]
This parameter is only accessible on the graphic display terminal if
[2 param. sets]
is not at
[No]
(nO)
.
Making an entry in this parameter opens a window containing all the adjustment parameters that can be accessed.
Select 1 to 15 parameters with the ENT key (a check mark appears by your selections) or cancel the parameter selection with ESC.
Example:
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
Ramp increment
SELECTED PARAMETERS
1.3 SETTINGS
PS1-
[SET 1]
The parameter is accessible if at least 1 parameter in the
[SELECTED. PARAMETERS]
has been selected.
Making an entry in this parameter opens a settings window containing the selected parameters
in the order in which they were selected
.
With the graphic display terminal:
RDY
Term
+0.00 Hz
0 A
Start up:
<<
>>
Quick
ENT
Startup time
9.51 s
Min = 0.1 Max = 999.9
9.67 s
12.58 s
13.45 s
2.3 s
9.51 s
RDY
Term
+0.00 Hz
0 A
SET1
Start up:
Deceleration:
Acceleration 2:
Code
<<
>>
Quick
Deceleration 2:
Begin Acc round:
With integrated display terminal:
Proceed as in the Settings menu using the parameters that appear.
PS2-
[SET 2]
The parameter is accessible if at least 1 parameter in the
[SELECTED. PARAMETERS]
has been selected.
Procedure identical to
[PARAMETER SET 1]
(PS1-)
.
PS3-
[SET 3]
The parameter is accessible if
[3 parameter set]
is not
[No]
(nO)
and if at least 1 parameter has been selected in
[SELECT. PARAMETER]
.
Procedure identical to
[PARAMETER SET 1]
(PS1-)
.
Note:
We recommend that a parameter set switching test is carried out while stopped and a check is made
to ensure that it has been performed correctly. Some parameters are interdependent and in this case
may be restricted at the time of switching.
The mutual dependency of parameters must be taken into account, even between different sets.
Example: The highest
[low frequency]
(LSP)
must be lower than the lowest
[high frequency]
(HSP)
.
Содержание 8I84T200037.01P-1
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...