![B&R 8I84T200037.01P-1 Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/bandr/8i84t200037-01p-1/8i84t200037-01p-1_user-manual_460473106.webp)
Programming guidelines
106
ACOPOSinverter P84 User's Manual 2.10
2.6.3 Codes for the inverter state:
ACC
Startup time
CLI
Current limiting
CTL
Controlled stop in the event of a failure of the input phase
DCB
DC injection is taking place
DEC
Deceleration
FLU
Motor magnetizing taking place
FST
Fast stop
NLP
No power supply (No mains voltage on L1, L2, L3)
NST
Freewheel stop
OBR
Automatically adjusted deceleration
PRA
Power removal function (safe stop) active (inverter locked)
RDY
Drive ready
RUN
The inverter is running.
SOC
Controlled output shutdown
TUN
Autotuning taking place
USA
Low voltage alarm