![B&R 8I84T200037.01P-1 Скачать руководство пользователя страница 105](http://html1.mh-extra.com/html/bandr/8i84t200037-01p-1/8i84t200037-01p-1_user-manual_460473105.webp)
Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
105
2.6.2 Description of the screen
RDY
1 DRIVE MENU
1.2 MONITORING
1.3 SETTINGS
Term
0.0 Hz
0.0 A
Code
Quick
1.1 SIMPLY START
<<
>>
1.4 MOTOR CONTROL
1.5 INPUTS / OUTPUTS CFG
F1
F2
F3
F4
1
2
3
4
6
5
1.
Display line. The content can be configured. The following is shown in the factory setting:
•
see "Codes for the inverter state:" on page 106
•
The active control channel:
– Term: Terminals
– HMI: Graphics terminal
– CAN: Integrated communication interface
– NET: Communication card
•
Frequency reference
•
Current in the motor
2.
Menu bar: Displays the name of the current menu or submenu.
3.
The menus, submenus, parameters, values, bar charts, etc., are displayed in the drop-down window format
on up to 5 lines. Selected lines and values are displayed with light characters on a dark background using the
navigation button.
4.
Section in which the functions assigned to keys F1 to F4 are displayed via these, for example:
Code
F1
Displays the code of the selected parameter (in accordance with the 7-segment display).
HELP
F1
Context help
<<
F2
Navigate horizontally to the left or to return to the previous menu/submenu or (in the case of values) to switch the next higher position
(displayed with light characters on a dark background,
see "Example configuration window for one value:" on page 107
>>
F3
Navigate horizontally to the right or to switch to the previous menu/submenu or (in the case of values) to the next lower position (displayed
with light characters on a dark background,
see "Example configuration window for one value:" on page 107
Quick
F4
see "Quick navigation" on page 111
The function keys are dynamic and context-dependent.
These keys can be assigned to other functions (application functions) via the menu
[CONTROL]
.
If a preset speed is assigned to a function key and then the function key is pressed, the motor runs with the preset
speed, until a different preset speed or JOG is pressed, the speed reference is changed or the stop button is
pressed.
Indicates that there are no further levels below this display window.
5.
Indicates that there are more levels beneath this display window.
Indicates that you can no longer scroll this display window up any further.
6.
Indicates that there are more levels above this display window.
Содержание 8I84T200037.01P-1
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...