MN761
Parameter Descriptions 7-1
Chapter 7
Parameter Descriptions
7.1
Drive Group
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Speed Reference
(Range: 0.00 to 400.00 Hz) Must be less than F21.
The value of the speed reference command. The commanded speed
(frequency) is displayed even if the drive is not running.
Preset Value:
0.00
RW
Acceleration Time
(Range: 0-6000seconds)
Sets acceleration time.
During Preset Speed operation, serves as acceleration time 0.
Preset Value:
0
RW
Deceleration Time
(Range: 0-6000seconds)
Sets deceleration time.
During Preset Speed operation, serves as deceleration time 0.
Preset Value:
0
RW
Start/Stop Source
(Range:
0- Run/Stop by Run/Stop key on the keypad.
1- 2 or 3 wire control from the terminal strip.
2- 2 wire with direction control from the terminal strip.
3- Operation by Communication Option)
Sets the control mode to keypad, terminal strip, communication network.
Preset Value:
0.0
RW
Speed Reference Source
(Range:
0- Digital, by Keypad 1
1- Digital, by Keypad 2
2- Analog, by Keypad Potentiometer (V0)
3- Analog, by V1 Terminal
4- Analog, by I Terminal
5- Analog, by Keypad Potentiometer and I Terminal
6- Analog, by V1 Terminal and I Terminal
7- Analog, by Keypad Potentiometer and V1 Terminal
8- Analog, by Modbus-RTU Communication
Sets the speed reference source of the drive to be from the drive keypad or
a remote analog reference.
Preset Value:
0.00
RW
Preset Speed 1
(Range: 0-400 Hz) Must be less than F21.
Sets Preset Speed 1 during operation. See also I30-I33.
Preset Value:
10.00
RW
Preset Speed 2
(Range: 0-400 Hz) Must be less than F21.
Sets Preset Speed 2 during operation. See also I30-I33.
Preset Value:
20.00
Содержание VS1SM
Страница 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Страница 10: ...2 2 General Information and Ratings MN761...
Страница 28: ...6 8 Using the Keypad MN761...
Страница 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Страница 58: ...8 2 Customizing for Your Application MN761...
Страница 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Страница 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Страница 69: ...Baldor District Offices...
Страница 71: ...Series VS1SM Single Phase AC Control MN761...