7-18 Parameter Descriptions
MN761
7.3 Function Group2
Continued
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Second Motor Stall Prevention Level
(Range: 30-150%)
Sets the current level that activates stall prevention for the second motor
during Accel, Constant, or Decel. Set as a percentage of H90.
Preset Value:
150
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Second Motor 1 Minute Overload
(Range: 50-200%)
Sets the maximum current level the motor can tolerate for 1 minute set as a
percentage of H90. Cannot be less than H89.
Preset Value:
150
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Second Motor Continuous Overload
(Range: 50-150%)
Sets the maximum current level the motor can tolerate for continuous
operation set as a percentage of H90. Cannot be greater than H88.
Preset Value:
100
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Second Motor Rated Current
(Range: 0.1-20A)
Sets the rated current for the second. See motor nameplate.
Preset Value:
1.8
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Factory Settings
(Range:
0- None.
1- All parameter values are restored to factory settings.
2- Only Drive Group parameter values are restored to factory settings.
3- Only Function Group 1 parameter values are restored to factory settings.
4- Only Function Group 2 parameter values are restored to factory settings.
5- Only I/O Group parameter values are restored to factory settings.)
Initializes parameter values to factory settings.
Preset Value:
0
RW
Password Registration
(Range: 0-FFF)
Set password for H95.
Valid password is 3 hexadecimal characters (0-9, A, B, C, D, E, F).
Preset Value:
0
RW
Parameter Lock and Unlock
(Range: )
0- Unlocked Parameter changes allowed.
1- Locked Parameter changes NOT allowed.
Locks or Unlocks parameters by entering the password registered in H94.
Preset Value:
0
Содержание VS1SM
Страница 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Страница 10: ...2 2 General Information and Ratings MN761...
Страница 28: ...6 8 Using the Keypad MN761...
Страница 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Страница 58: ...8 2 Customizing for Your Application MN761...
Страница 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Страница 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Страница 69: ...Baldor District Offices...
Страница 71: ...Series VS1SM Single Phase AC Control MN761...