7-6 Parameter Descriptions
MN761
7.2 Function Group1
Continued
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Volts/Hz Pattern
(Range:
0- Linear. Maintains a linear Volts/Hz ratio from F23 to F22.
1- Square. Maintains a squared Volts/Hz ratio.
2- User Defined. Volts/Hz ratio adjusted for specialized motors and load
characteristics.
When User Volts/Hz pattern is active, F28 and F29 are deactivated.
Preset Value:
0
Run
Freq.
Start freq.
Base freq.
F req.
Base f req.
100%
Voltage
Freq.
Voltage
Start
freq.
F3 1
F33 F35 F37 Base
freq.
F32
F34
F36
F38
100%
Linear
V/Hz
Rated Volts
Output Volts
User Defined
Square
Linear
RW
User V/F Frequency 1
(Range: 0-400Hz)
Sets Frequency 1 in User Defined V/F Pattern. See also F32.
Cannot be greater than F21, F33, F35 or F37.
Preset Value:
15.00
Parameter is only displayed when F30=2.
RW
User V/F Volts 1
(Range: 0-100%)
Sets Voltage 1 in User Defined V/F Pattern as a % of ?? See also F31.
Cannot be greater than F34, F36 or F38.
Preset Value:
25
Parameter is only displayed when F30=2.
RW
User V/F Frequency 2
(Range: 0-400Hz)
Sets Frequency 2 in User Defined V/F Pattern. See also F34.
Cannot be greater than F21, F35 or F37.
Preset Value:
30.00
Parameter is only displayed when F30=2.
RW
User V/F Volts 2
(Range: 0-100%)
Sets Voltage 2 in User Defined V/F Pattern as a % of ?? See also F33.
Cannot be greater than F36 or F38.
Preset Value:
50
Parameter is only displayed when F30=2.
RW
User V/F Frequency 3
(Range: 0-400Hz)
Sets Frequency 3 in User Defined V/F Pattern. See also F36
Cannot be greater than F21 or F37.
Preset Value:
Parameter is only displayed when F30=2.
RW
User V/F Volts 3
(Range: 0-100%)
Sets Voltage 3 in User Defined V/F Pattern as a % of ?? See also F35.
Cannot be greater than F38.
Preset Value:
45.00
Parameter is only displayed when F30=2.
Содержание VS1SM
Страница 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Страница 10: ...2 2 General Information and Ratings MN761...
Страница 28: ...6 8 Using the Keypad MN761...
Страница 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Страница 58: ...8 2 Customizing for Your Application MN761...
Страница 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Страница 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Страница 69: ...Baldor District Offices...
Страница 71: ...Series VS1SM Single Phase AC Control MN761...