5-4 Troubleshooting
MN715J
How to Access the Fault Log
When a fault condition occurs, motor operation stops and a fault code is
displayed on the Keypad display. The control keeps a log of the last 31 faults.
If more than 31 faults have occurred, the oldest fault will be deleted from the
fault log. To access the fault log, perform the following procedure:
Action
Description
Display
Apply Power
Display of mode & drive status.
Press DISP key
Press DISP to scroll to the Fault Log
entry point.
Press ENTER key
Display first fault type and time fault
occurred.
Press
Y
key
Scroll through fault messages.
Press ENTER key
Scroll to diagnostic info block.
Press RESET key
Return to display mode.
How to Clear the Fault Log
Use the following procedure to clear the fault log.
Action
Description
Display
Apply Power
Display of mode & drive status.
Press DISP key
several times
Scroll to diagnostic info block.
Press DISP key
Press DISP to scroll to the Fault Log
entry point.
Press ENTER key
Displays most recent message.
Press SHIFT key
Press RESET key
Press SHIFT key
Press ENTER key
Fault log is cleared.
Содержание ID15J1F50-ER
Страница 1: ...Series 15J Inverter Control 7 04 MN715J Installation and Operating Manual...
Страница 5: ...iv Table of Contents MN715J...
Страница 11: ...2 4 General Information MN715J...
Страница 59: ...4 22 Programming and Operation MN715J...
Страница 75: ...6 6 Specifications and Product Data MN715J...
Страница 79: ...A 4 Dynamic Brake Hardware MN715J...
Страница 86: ...Appendix C Remote Keypad Mounting Template MN715J Remote Keypad Mounting Template C 1...