MN715J
Programming and Operation 4-3
Operation Examples
Operating the Control from the Keypad
If the control is configured for remote or serial control, the LOCAL Mode must
be activated before the control may be operated from the keypad. To activate
the LOCAL Mode, first the motor must be stopped using the keypad STOP
key (if enabled), remote commands or serial commands.
Note: Pressing the keypad STOP key (if enabled) will automatically issue a motor
stop command and change to LOCAL mode.
When the motor has stopped, the LOCAL Mode is activated by pressing the
“LOCAL” key. Selection of the LOCAL Mode overrides any remote or serial
control inputs except for the External Trip input, Local Enable Input or STOP
input.
The control can operate the motor in three (3) different ways from the keypad.
1.
JOG Command.
2.
Speed adjustment with Keypad entered values.
3.
Speed adjustment using the Keypad arrow keys.
Note: If the control has been configured for Keypad in the operating mode
parameter (level 1, input block), then no other means of operation is permitted
other than from the keypad.
Accessing the Keypad JOG Command
Action
Description
Display
Apply Power
If no faults and programmed for
LOCAL operation.
Press JOG key
Access programmed JOG speed.
Press and hold
FWD or REV key
Move control forward or reverse at
JOG speed.
Press JOG key
Disables JOG mode.
Содержание ID15J1F50-ER
Страница 1: ...Series 15J Inverter Control 7 04 MN715J Installation and Operating Manual...
Страница 5: ...iv Table of Contents MN715J...
Страница 11: ...2 4 General Information MN715J...
Страница 59: ...4 22 Programming and Operation MN715J...
Страница 75: ...6 6 Specifications and Product Data MN715J...
Страница 79: ...A 4 Dynamic Brake Hardware MN715J...
Страница 86: ...Appendix C Remote Keypad Mounting Template MN715J Remote Keypad Mounting Template C 1...