MN715J
Receiving and Installation 3-25
EPOT 3 Wire Connection
Figure 3-19 Electronic POT 3 Wire Connection Diagram
11
12
13
14
15
16
17
18
Forward
Reverse
Stop
Accel/Decel Select
Increase
Decrease
External Trip
Input Common
Refer to Figure 3Ć9.
J4
See recommended terminal
tightening torques in Section 6.
J4-11
Momentary CLOSED starts Forward motor rotation.
J4-12
Momentary CLOSED starts Reverse motor rotation.
J4-13
Momentary OPEN motor decels to stop (depending on Keypad Stop mode).
J4-14
OPEN selects ACC / DEC / S-CURVE group 1.
CLOSED selects group 2.
J4-15
Momentary CLOSED increases motor speed while closed.
J4-16
Momentary CLOSED decreases motor speed while closed.
J4-17
If J4-17 is connected, you must set Level 2 Protection block, External Trip to
“ON” to activate the opto input.
OPEN causes an external trip fault. The control will disable and the motor
coasts to a stop. An external trip fault is displayed (also logged in the fault log).
CLOSED allows normal operation.