© 2018 Baker Hughes, a GE company, LLC. All rights reserved.
Masoneilan SVI II ESD Quick Start Guide
=
|
29
3. Place the Quarter Turn Mounting Plate into place sliding it through the
anti-backlash spring into the dowel pin at the end of the plate into the hex head
screw installed in step 2.
4. Secure the plate to the bracket using four (4) flat head cap screws.
50 mm Mounting
Tools required:
3 mm hex key
4 mm hex key
Refer to Figure 5 for this procedure.
To mount using this kit:
1. Attach the mounting bracket to the valve actuator using four (4) M5 x 0.8 x 10
flat-head cap screws.
2. Place the indicator disk with metal insert over the valve actuator shaft.
Figure 5 Namur 50 mm Mounting Kit
3. Place the Namur coupling and lever on top of the indicator disc and secure with
an M6 x 1.0 x 25 socket-head screw.
4. Place the Quarter Turn Mounting Plate into place sliding it over the lever and
through the anti-backlash spring.
5. Secure the bracket using four (4) flat head cap screws.
Mounting Bracket
Indicator Disc Bracket
Namur coupling
w/lever
Anti-backlash spring
Quarter Turn
Mounting Plate