© 2018 Baker Hughes, a GE company, LLC. All rights reserved.
86 |
=
BHGE
Doc Number ES-727
Revision
W
PDR ECO-
0029774
11/15/2017
Written By
P.Levesque
13DEC2006
Checked
T.Kabir
10JAN2007
Filename
ES-727.DOC
Page 8 of 13
Approved
T. Kabir
10JAN2007
Copyright 2017 as an unpublished trade secret. This document and all information herein is the property of
Dresser LLC.
It is confidential
and must not be made public or copied and is subject to return upon demand.
II 2G Ex db mb IIC T6..T4 Gb
{Flameproof/Encapsulation, gas}
II 2D Ex tb IIIC T96°C Db
{Protection by Enclosure, dust}
FM17ATEX0093X {Certificate Number}
II 3G Ex ic IIC T6..T4 Gc
{Intrinsically Safe, gas}
II 3D Ex tc IIIC T96°C Dc
{Protection by Enclosure, dust}
(IEC)
IECEx FMG 07.0007X
{Certificate Number}
Ex ia IIC T6..T4 Ga
{Intrinsically Safe}
Ex db mb IIC T6..T4 Gb
{Explosionproof, gas}
Ex tb IIIC T96°C Db
{Protection by enclosure, dust}
Ta=-40°C to +85°C
{Operating Temperature}
IP66
{Ingress
Protection}
7.3
Operating Ranges
7.3.1
Temp: -40°C to +85°C
7.3.2
Voltage: 30 Volts
7.3.3
Pressure: 150 psig (1.03MPa)
7.3.4
Current: 4-20mA
7.4
Enclosure Type
Type 4X-IP66
7.5
Temperature Code
T6 Ta=60°C, T5 Ta=75°C, T4 Ta=85°C
7.6
Notes Related to Explosionproof Rating
DO NOT OPEN EVEN WHEN ISOLATED WHEN EXPLOSIVE ATMOSPHERES ARE
PRESENT
7.7
Notes Related to Intrinsic Safety
1) REFER TO ES-727 FOR ADDITIONAL CAUTIONS OR WARNINGS
2) Supply Connection Wiring Rated for 5ºC Above Max Ambient
3) PERMANENTLY MARK THE PROTECTION TYPE CHOSEN. ONCE THE TYPE
HAS BEEN MARKED, IT CAN NOT BE CHANGED
7.8
Model Code:
SVI2-abcdefgh
(see section 4 above for explanation)