Chapter
1.
Introduction
1.7 Hard Key Functions
1.8 Soft Keys
Three soft keys, designated
F1
,
EXIT
and
F2
, are situated immediately below the display as
shown below. These keys have their function allocated by the instrument software which is
indicated in the bottom of the display (Voltage for
F1
and Units for
F2
in this example). They are
used to select menu (program) options and are fully described under the appropriate section
headings.
1.9 Cursor Keys
The cursor keys consist of a block of four keys, designated
up
,
down
,
left
, and
right
.
In programs where options need to be selected from a list, (e.g.) the
TASK
selection program,
the
up
and
down
cursor keys are used to highlight one of the options, from which it can be
Table
1
-
3: Hard Key Functions
Key
Function
I/O
This key selects the instrument ON and OFF.
SETUP
a
a. These key functions are not available in BASIC mode.
The
SETUP
key provides access to the instrument’s general
configuration parameters that are set-up to certain default parameters
on delivery.
ZERO
The
ZERO
key zeros either the selected input or output display, only if
the display reading is within 5% of zero. Attempts to zero a larger offset
result in an error message,
Zero too large
.
INPUT
a
The
INPUT
key selects the input parameter to be displayed.
TASK
The
TASK
key rapidly configures the instrument for a number of
different types of external device calibration. There are twenty task
configurations available, eleven pre-programmed configurations and
nine user defined configurations.
OUTPUT
a
The
OUTPUT
key selects the output parameter to be displayed.
STORE
a
Depending upon how the instrument’s
STORE
mode is set-up, this key
is used either to store up to 20 display screens in
SNAPSHOT
mode,
or to manually log a screen in
DATALOG
mode.
RECALL
a
This key recalls a previously stored screen to the display. Depending
on the
STORE
mode set-up, operation of this key recalls either the
snapshot of a previously stored screen or data log file. In
STORE
mode, selection displays the last screen stored. By using the cursor
keys, the operator can scroll either forward or back through memory
locations.
ENTER
The
ENTER
key either enters data (accept entered data), or, in
conjunction with the soft keys, accepts a given selection.
EXIT
The
EXIT
key operates in conjunction with all the other hard and soft
keys to exit from the current screen or menu level, to the level
immediately preceding it. To quit completely from any menu level,
press
EXIT
until the
MEASURE/SOURCE
screen is displayed.
Содержание Druck DPI 610 IS
Страница 1: ...Druck com DPI 610 615 IS Intrinsically Safe Portable Pressure Calibrator Instruction Manual...
Страница 2: ......
Страница 6: ...Copyright 2007 Baker Hughes Company iv DPI 610 615 IS Instruction Manual English...
Страница 10: ...Copyright 2007 Baker Hughes Company viii DPI 610 615 IS Instruction Manual English...
Страница 20: ...Copyright 2007 Baker Hughes Company 10 DPI 610 615 IS Instruction Manual English Chapter 2 Getting Started...
Страница 38: ...Copyright 2007 Baker Hughes Company 28 DPI 610 615 IS Instruction Manual English Chapter 5 Advanced Task...
Страница 64: ...Copyright 2007 Baker Hughes Company 54 DPI 610 615 IS Instruction Manual English Chapter 8 Calibration...
Страница 75: ......