background image

Visit Elsag Bailey on the World Wide Web at http://www.bailey.com

Our worldwide staff of professionals is ready to meet 

your needs for process automation. 

For the location nearest you, please contact the appropriate regional office.

AMERICAS
29801 Euclid Avenue
Wickliffe, Ohio USA 44092
Telephone 1-216-585-8500
Telefax 1-216-585-8756

ASIA/PACIFIC
152 Beach Road
Gateway East #20-04
Singapore 189721
Telephone 65-391-0800
Telefax 65-292-9011

EUROPE, AFRICA, MIDDLE EAST
Via Puccini 2
16154 Genoa, Italy
Telephone 39-10-6582-943
Telefax 39-10-6582-941

GERMANY
Graefstrasse 97
D-60487 Frankfurt Main
Germany
Telephone 49-69-799-0
Telefax 49-69-799-2406

Form I-E96-415A Litho in U.S.A. 193
Copyright © 1993 by Elsag Bailey Process Automation, As An Unpublished Work
® Registered Trademark of Elsag Bailey Process Automation
™ Trademark of Elsag Bailey Process Automation

Содержание Infi 90 NIRL03

Страница 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 415 Remote Link Termination Module NIRL03...

Страница 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Страница 3: ...between IMRIO02 Remote I O Slave Modules Station link communications from an IMRIO02 module to IISAC01 Analog Control Stations NDCS03 Digital Control Stations and NDIS01 Digital Indicator Stations Th...

Страница 4: ...hrough A 2 Original B 1 through B 4 Original C 1 through C 3 Original D 1 through D 2 Original Index 1 Original When an update is received insert the latest changed pages and dispose of the super sede...

Страница 5: ...or of the cabinet containing these externally powered circuits must be marked with a warning stating that multiple power sources exist p 2 9 SPECIFIC CAUTIONS Remove modules slave master or terminatio...

Страница 6: ...ation Le cas echeant un avertissement signalant la presence de sources d alimentation multiples doit entre appose sur la porte de l armoire p 2 9 ATTENTIONS D ORDRE SP CIFIQUE Retirer les modules asse...

Страница 7: ...7 NKTL01 Cable 2 7 NKTU02 and NKTU12 Cables 2 8 Installing the Termination Module 2 8 Terminal Wiring 2 8 SECTION 3 MAINTENANCE 3 1 INTRODUCTION 3 1 MAINTENANCE SCHEDULE 3 1 SECTION 4 REPAIR REPLACEME...

Страница 8: ...of Terms and Abbreviations 1 3 1 3 Nomenclature 1 3 1 4 Specifications 1 4 2 1 Jumper J3 Settings 2 4 2 2 NIRL03 Cable Applications 2 4 3 1 Maintenance Schedule 3 1 5 1 Spare Parts List 5 1 A 1 IMRIO...

Страница 9: ...ation INTENDED USER System engineers and technicians should read this manual before installing and placing the NIRL03 termination module into operation Do not put the IRL termination module into opera...

Страница 10: ...t the quick reference information necessary to configure IMRIO02 modules and NDIS01 NDCS03 and IISAC01 stations HOW TO USE THIS MANUAL Read this manual through in sequence Read the installation sectio...

Страница 11: ...l and communication support for INFI 90 Network 90 modules QRS Quick response slave module RMP Remote master processor RSP Remote slave processor Serial Link Wire Two insulated 22 gauge wires twisted...

Страница 12: ...ination mounting unit Inputs Remote communication link from another IRL termination module Serial communication link to attached stations Outputs Remote communication link to another IRL termination m...

Страница 13: ...ment and static safe practices when working with modules 1 Use Static Shielding Bag Keep the modules in the static shielding bag until you are ready to install them in the system Save the packaging fo...

Страница 14: ...mber 194776A11001 should be installed in fuse clip F1 A five amp 250 volt fuse Bailey part number 194776A15001 should be installed in fuse clip F2 NIRL03 termination modules with a revision level of R...

Страница 15: ...INAL 1 1 AMP FUSE F1 5 AMP FUSE F2 J4 CONNECTOR FOR NKTD02 12 TERMINAL 11 TERMINAL 25 J1 AND J2 CONNECTOR FOR COAXIAL CABLE TERMINAL 32 T00540A APPLICATION SELECTION JUMPER J3 COAX UNTRM TWAX 1 2 3 4...

Страница 16: ...ions Max Length m ft NKCL01 PVC communication cable Connect an IRL module to another IRL module The end of one NKTL01 cable to the end of another NKTYL01cable 3 000 10 000 NKCL02 non PVC communication...

Страница 17: ...tion Connections Max Length m ft REMOTE IMRIO02 RSP NKTU02 12 NKTU02 12 NKTL01 NKCL01 02 NKPL03 04 NKTL01 NIRL03 SERIAL LINK WIRE NICS01 NIDS01 NKTU02 12 RIBBON CABLE 6634408A2 NKTD01 11 NKDS01 11 NKT...

Страница 18: ...le of the remote slave pro cessor RSP IRL module 2 Connect the other conductor from terminal 8 or TB3 2 depending on firmware revision of IRL module of the local RMP IRL module to terminal 25 or TB4 2...

Страница 19: ...or P1 of the station cir cuit board connects to this end of the cable 3 Insert the J1 end of the cable into the J4 connector of the IRL module The cable should latch securely into place 4 Install the...

Страница 20: ...The cable should latch securely into place Card edge connector P1 of the IRL module connects to this end of the cable 6 Insert the IMRIO02 slave module into the MMU until it locks into place 7 Replac...

Страница 21: ...ation multiples doit entre appose sur la porte de l armoire CAUTION It is strongly recommended that all power cabinet I O etc be turned off before doing any termination module wiring Failure to do so...

Страница 22: ...odule 4 Connect an 18 AWG wire from the common bus of the ter mination mounting unit to the common terminal of the IRL module 5 Insert the IRL module until it locks securely into place 6 Replace snap...

Страница 23: ...MAINTENANCE SCHEDULE Execute the tasks in Table 3 1 at the specified intervals Table 3 1 Maintenance Schedule Task Interval Clean and tighten all power and field wiring connections Every 6 months or...

Страница 24: ...acement IRL module If not already installed insert the appropriate fuses into fuse clips F1 and F2 6 Set the jumpers on the replacement IRL module to match the jumper settings of the defective IRL mod...

Страница 25: ...se 5 Install the replacement fuse into the appropriate fuse clip 6 Insert the IRL module until it locks securely into place 7 Install snap on the front cover of the IRL module 8 Apply power to the cab...

Страница 26: ...identifies the part Order parts without commercial descriptions from the nearest Bailey Controls Company sales office TRAINING Bailey Controls Company has a modern training facility avail able for tra...

Страница 27: ...ave Module instruction manual for detailed instructions Figure A 1 Remote I O Slave Module Table A 1 IMRIO02 Dipswitch S1 Address Examples 1 Address Example Dipswitch Position Binary Value 12 128 22 6...

Страница 28: ...able A 3 IMRIO02 Dipswitch S3 Communication Cables Dipswitch Position Function 1 2 3 4 5 6 7 8 X X X 2 1 0 0 0 Remote RSP mode X X X 2 0 1 1 1 Local RMP mode NOTE 0 CLOSED or ON 1 OPEN or OFF X any di...

Страница 29: ...output and electric drive options dipswitch S2 along with the bar graph display option dipswitches S3 and S4 must be set Jumpers JP1 through JP3 set the manual override electric drive type and normal...

Страница 30: ...able auto bypass Disable auto bypass Demand Output 1 0 Reverse DO output Normal DO output Electric Drive 1 0 Enable electric drive Disable electric drive NOTE 0 CLOSED or ON 1 OPEN or OFF Table B 3 II...

Страница 31: ...0 AI2 SP CO PV SP CO3 1 0 1 AI2 SP AI1 PV SP CO3 1 1 0 AI2 SP Blank PV SP CO3 1 1 1 AI2 SP All On PV SP CO3 Bypass Mode 0 0 0 01 Blank Blank AI1 DO2 0 0 0 1 Blank Blank DO DO 0 0 1 0 AI1 Blank DO DO...

Страница 32: ...This jumper is labeled JP4 on stations that are revision 6638095A1 Table B 6 Electric Drive Mode Display Options Stand Alone Display Mode Dipswitch S3 Positions 1 Bypass Display Mode Dipswitch S4 Pos...

Страница 33: ...ng the NIRL03 termination module Configuration consists of setting the analog input type dipshunt XU16 and control output type jumpers J1 and J2 on the bypass board Setting the station address dipswit...

Страница 34: ...lectric drive analog input1 1 1 0 0 0 0 1 1 4 to 20 mA analog input NOTES 0 open or cut strap 1 intact or shorted strap 1 Connected to the 4 to mA output locally Table C 2 NDCS03 Jumper J1 and J2 Cont...

Страница 35: ...e auto bypass 2 3 Disable auto bypass JP2 1 2 Enable reverse acting output when in bypass 2 3 Disable reverse acting output when in bypass JP3 1 2 No external analog input displayed on OUT bar graph w...

Страница 36: ...reference guide for per sonnel installing the NIRL03 termination module Configura tion consists of setting the station address dipswitch S1 and display brightness jumper JP1 Refer to the NDIS01 Digit...

Страница 37: ...1 DIGITAL INDICATOR STATION CONFIGURATION INTRODUCTION D 2 I E96 415A Table D 2 NDIS01 Jumper JP1 Display Brightness Jumper Jumper Position Function JP1 1 2 Select bright intensity 2 3 Select dim inte...

Страница 38: ...ntended user 1 1 J Jumpers 2 2 5 1 M Maintenance schedule 3 1 Module Replacement procedures 4 1 N NDCS03 configuration C 1 NDIS01 configuration D 1 O Overview 1 1 R References 1 2 Related equipment 1...

Страница 39: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Отзывы: