MASTER
–
Instruction manual
Chap. 7
-
20
/
31 -
7.2.37
Alarm 49 – SPINDLE NOT ACTIVATED
ALARM 49 – SPINDLE NOT ACTIVATED
1 of 1
CONDITION / CHECK
DESCRIPTION
MALFUNCTION
Spindle start up attempt not activated.
POSSIBLE CAUSE
There are various possible causes:
Inverter off or in alarm state
Spindle-inverter connection problem
Inverter-PLC input connection problem
SOLUTION
Enable the ENABLE SPINDLE SK
In automatic, from programme, check the presence of the M3 code in
the piece programme (or in the MASTER)
Содержание MASTER
Страница 4: ...Chap 0 IV 4 Page intentionally left blank ...
Страница 5: ...CHAPTER 1 Foreward Chap 1 1 16 1 Foreword CHAPTER ...
Страница 7: ...CHAPTER 1 Foreward Chap 1 3 16 Page intentionally left blank ...
Страница 20: ...MASTER Instruction Manual Chap 1 16 16 Page intentionally left blank ...
Страница 21: ...CHAPTER 2 Safety information Chap 2 1 36 2 Safety information CHAPTER ...
Страница 56: ...MASTER Instruction Manual Chap 2 36 36 Page left intentionally blank ...
Страница 57: ...Chap 3 1 27 CHAPTER 3 Machine description and technical data 3 Machine description and technical data CHAPTER ...
Страница 59: ...Chap 3 3 27 CHAPTER 3 Page intentionally left blank ...
Страница 83: ...Chap 3 27 27 CHAPTER 3 ...
Страница 84: ...CHAPTER 4 Installation Chap 4 1 32 4 Installation CHAPTER ...
Страница 110: ...CHAPTER 4 Installation Chap 4 27 32 ANCHORING THE TGV TABLES 2 of 3 STEP ACTION DESCRIPTION 3 Positioning diagram ...
Страница 116: ...CHAPTER 5 Controls and Use of the machine Chap 5 1 62 5 Controls and use of the machine CHAPTER ...
Страница 178: ...CHAPTER 6 Maintenance Chap 6 1 30 6 Maintenance CHAPTER ...
Страница 207: ...MASTER Instruction Manual Chap 6 30 30 Page left intentionally blank ...
Страница 208: ...CHAPTER 7 Messages Alarms Chap 7 1 31 7 Messages Alarms CHAPTER ...
Страница 238: ...CHAPTER 7 Messages Alarms Chap 7 31 31 Page left intentionally blank ...