38
07 - 2009
3
Clean the dirt on the sensors and on the optic prism situated in the cover.
It is recommended to use compressed air. For operations in the field, you may use
aerosol. If the dirt is difficult to remove, you may use a cotton cloth impregnated with
ethylic alcohol 96º.
4
Replace the cover to its original position.
6.3 MECHANICAL CONFIGURATION OF THE CHANGE RETURN RANGE
The standard configuration of the T3 hopper has a very wide range of use and allows the
management of the majority of coins in the market.
The standard configuration is designed for diameters between 18 and 26 mm and thicknesses
of 1.5 to 3.2 mm. There are mechanical configurations for a range of small coins (CONFIG.
INFO: track 1, extraction base and stirrer) that accommodates the diameters between 16.25 to
22 mm and a configuration for larger coins (CONFIG. SUP) with a range from 24 to 32.50 mm.
To configure a different range of coins, follow the steps below:
1
It is necessary to access the extraction assembly, to do this, follow the steps
indicated in point
6.1 DISASSEMBLY AND ASSEMBLY.
2
First disconnect the cable on the sensorisation board and then remove the
extraction assembly and proceed to disassemble it.
3
Turn the extraction assembly 180º to access the oposite face.
For this operation you need:
•
Philips screwdriver with a PH 0 point.
•
Compressed air or an aerosol.
Occasionally:
•
Ethylic alcohol 96º
•
Cotton cloth or cotton buds.